EVS-EN ISO 14708-2:2022

Kirurgilised implantaadid. Aktiivsed implanteeritavad meditsiiniseadmed. Osa 2: Südamestimulaatorid

Üldinfo

Kehtiv alates 16.08.2022
Alusdokumendid
ISO 14708-2:2019; EN ISO 14708-2:2022
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
16.08.2022
Põhitekst
This document specifies requirements that are applicable to those active implantable medical devices intended to treat bradyarrhythmias and devices that provide therapies for cardiac resynchronization.
The tests that are specified in this document are type tests, and are to be carried out on samples of a device to show compliance.
This document was designed for bradyarrhythmia pulse generators used with endocardial leads or epicardial leads. At the time of this edition, the authors recognized the emergence of leadless technologies for which adaptations of this part will be required. Such adaptations are left to the discretion of manufacturers incorporating these technologies.
This document is also applicable to some non-implantable parts and accessories of the devices (see Note 1).
The electrical characteristics of the implantable pulse generator or lead are determined either by the appropriate method detailed in this particular standard or by any other method demonstrated to have an accuracy equal to, or better than, the method specified. In case of dispute, the method detailed in this particular standard applies.
Any features of an active implantable medical device intended to treat tachyarrhythmias are covered by ISO 14708-6.
NOTE 1    The device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, but there is a need to specify some requirements of non-implantable parts and accessories if they could affect the safety or performance of the implantable device.
NOTE 2    In this document, terms printed in italics are used as defined in Clause 3. Where a defined term is used as a qualifier in another term, it is not printed in italics unless the concept thus qualified is also defined.

Nõutud väljad on tähistatud *

*
*
*
PDF
31,72 € koos KM-ga
Paber
31,72 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 60601-2-3:2015

Elektrilised meditsiiniseadmed. Osa 2-3: Erinõuded lühilaineteraapia seadmete esmasele ohutusele ja olulistele toimimisnäitajatele
Uusim versioon Kehtiv alates 08.06.2015
Muudatus

EVS-EN 60601-2-3:2015/A1:2016

Elektrilised meditsiiniseadmed. Osa 2-3: Erinõuded lühilaineteraapia seadmete esmasele ohutusele ja olulistele toimimisnäitajatele
Uusim versioon Kehtiv alates 01.11.2016
Põhitekst

EVS-EN 45502-1:2015

Implantaadid kirurgias. Aktiivsed implanteeritavad meditsiiniseadmed. Osa 1: Üldnõuded ohutusele, märgistusele ja tootja antavale informatsioonile
Uusim versioon Kehtiv alates 08.06.2015
Põhitekst

EVS-EN ISO 14708-6:2022

Kirurgilised implantaadid. Aktiivsed implanteeritavad meditsiiniseadmed. Osa 6: Erinõuded tahhüarütmia raviks mõeldud aktiivsetele siirdatavatele meditsiiniseadmetele (sealhulgas siirdatavatele defibrillaatoritele)
Uusim versioon Kehtiv alates 16.08.2022