15.04.2020
Põhitekst
This part of IEC 61223 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose.
Excluded from the scope of this document are:
– MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC TOMOSYNTHESIS;
– 2D images synthesized from the tomosynthesis images
– reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS;
– CT SCANNERS covered by IEC 61223-3-5;
This part of IEC 61223 defines
a) the essential parameters which describe the acceptability criteria of MAMMOGRAPHIC TOMOSYNTHESIS modes of operation of MAMMOGRAPHIC X-RAY EQUIPMENT with regard to image quality and dose; and
b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances.
c) CONSTANCY TEST frequency when required
This part of IEC 61223 is intended to be applied along with the acceptability criteria included in IEC 61223-3-2 [1] or equivalent protocol for 2D mammography which are also relevant for MAMMOGRAPHIC TOMOSYNTHESIS modes of operation.
These methods mainly rely on non-invasive measurements that use appropriate test equipment and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance.
When the results of the ACCEPTANCE TEST are in compliance with the expected values, the BASELINE VALUES for the subsequent CONSTANCY TESTS are established.

Nõutud väljad on tähistatud *

*
*
*
PDF
31,72 € koos KM-ga
Paber
31,72 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN IEC 61223-3-5:2019

Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests and and constancy tests - Imaging performance of computed tomography X-ray equipment
Uusim versioon Kehtiv alates 15.11.2019
Põhitekst

EVS-EN 61223-3-2:2008

Evalveerimine ja tavakatsetused meditsiinipiltdiagnostika osakondades. Osa 3-2: Heakskiidukatsetused. Mammograafiliste röntgenseadmete pildistuskvaliteedi näitajad
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 61223-3-4:2002

Evalveerimine ja tavakatsetused meditsiinipiltdiagnostika osakondades. Osa 3-4: Heakskiidukatsetused. Hambaröntgenseadmete pildistuskvaliteedi näitajad
Uusim versioon Kehtiv alates 01.01.2003
Muudatus

EVS-EN 60601-2-45:2011/A1:2015

Elektrilised meditsiiniseadmed. Osa 2-45: Erinõuded mammograafiliste röntgenseadmete ja mammograafiliste stereotaktiliste seadiste esmasele ohutusele ja olulistele toimimisnäitajatele
Kehtiv alates 06.10.2015