EVS-EN IEC 60034-27-1:2018

Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines

Üldinfo

Kehtiv alates 16.07.2018
Alusdokumendid
IEC 60034-27-1:2017; EN IEC 60034-27-1:2018
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
16.07.2018
Põhitekst
05.04.2011
Põhitekst
This part of IEC 60034 provides a common basis for:
- measuring techniques and instruments;
- the arrangement of test circuits;
- normalization and testing procedures;
- noise reduction;
- the documentation of test results;
- the interpretation of test results, with respect to partial discharge off-line measurements on the winding insulation of rotating electrical machines.
The measurement methods described in this document are applicable to stator windings of machines with or without conductive slot coating and to the stator windings of machines made with form wound or random wound windings. In special cases like high voltage rotor field windings, this document is applicable as well. The measurement methods are applicable when testing with alternating sinusoidal voltages from 0,1 Hz up to 400 Hz.
Interpretation guidelines are given in this document and are applicable only if all the following requirements are fulfilled:
- Measurements performed with power frequency of 50 Hz or 60 Hz, or when testing with power supply within a frequency range of 45 Hz to 65 Hz.
- Form wound windings and winding components such as bars and coils.
- Winding with conductive slot coating. This is usually valid for machines with voltage rating of 6 kV and higher.
For machines with random wound windings, form-wound windings without conductive slot coating, and testing at frequencies differing from power frequencies, the interpretation guidelines are not applicable. The testing procedures for off-line PD-measurements of this document can be used for assessing the uniform quality of manufacturing or/and the trending of these kind of windings as well as converter driven machine windings.
NOTE Testing of low voltage machines with so called Type I insulation systems is defined in reference [10]1.
Testing procedures for qualification of converter driven high voltage machines with so called Type II insulation systems are dealt with in IEC 60034-18-42 (in addition to the optional electric tests described therein).

Nõutud väljad on tähistatud *

*
*
*
PDF
31,72 € koos KM-ga
Paber
31,72 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 60034-27-3:2016

Rotating electrical machines - Part 27-3: Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines
Uusim versioon Kehtiv alates 05.07.2016
Põhitekst

EVS-EN IEC 60034-27-4:2018

Rotating electrical machines - Part 27-4: Measurement of insulation resistance and polarization index on winding insulation of rotating electrical machines
Uusim versioon Kehtiv alates 16.07.2018