Skip to main content
Tagasi
UUS

EVS-EN IEC 60034-12:2024

Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors

Üldinfo

Kehtiv alates 15.11.2024
Alusdokumendid
IEC 60034-12:2024; EN IEC 60034-12:2024
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
15.11.2024
Põhitekst
05.07.2017
Põhitekst
IEC 60034-12:2024 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034‑1 that:
- have a rated voltage up to 1 000 V;
- are intended for direct-on-line or star-delta starting;
- are rated on the basis of duty type S1;
- are constructed to any degree of protection as defined in IEC 60034-5 and explosion protection.
This document also applies to dual voltage motors provided that the flux saturation level is the same for both voltages. This fourth edition cancels and replaces the third edition published in 2016. Aligned with the requirements for explosion protected motors from TC31 WG27
- new clause on methods for measuring locked-rotor current and torque;
- new informative annex on the general current and torque characteristics with locked rotor;
- new informative annex on correction of voltage and frequency;
- aligned with the requirements for explosion protected motors from TC31 WG27.

Nõutud väljad on tähistatud *

*
*
*
PDF
24,40 € koos KM-ga
Paber
24,40 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring