EVS-EN 60079-13:2017

Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

Üldinfo

Kehtiv alates 16.10.2017
Alusdokumendid
IEC 60079-13:2017; EN 60079-13:2017
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
16.10.2017
Põhitekst
05.01.2011
Põhitekst
IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer's facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer's facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.  This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p";
- addition of types of  protection "pb", "pc", and "vc"; and removal of types of protection "px", "py", "pz" and "pv";
- definition of the differences between pressurization and artificial ventilation types of protection;
- removal of protection of rooms with an inert gas or a flammable gas from the scope of this document;
- addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.

Nõutud väljad on tähistatud *

*
*
*
PDF
24,40 € koos KM-ga
Paber
24,40 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst + parandus

EVS-EN 60079-14:2014

Plahvatusohtlikud keskkonnad. Osa 14: Elektripaigaldiste kavandamine, seadmete valik ja paigaldamine
Uusim versioon Kehtiv alates 06.10.2014
Põhitekst

EVS-EN 60079-2:2015

Plahvatusohtlikud keskkonnad. Osa 2: Seadme kaitse survestatud ümbrise abil "p"
Uusim versioon Kehtiv alates 04.02.2015
Põhitekst

EVS-EN IEC 60079-10-1:2021

Plahvatusohtlikud keskkonnad. Osa 10-1: Piirkondade liigitus. Plahvatusohtlikud gaaskeskkonnad
Uusim versioon Kehtiv alates 01.03.2021
Põhitekst

EVS-EN 60079-29-1:2016

Plahvatusohtlikud keskkonnad. Osa 29-1: Gaasidetektorid. Põlevgaasidetektorite toimivusnõuded
Kehtiv alates 03.01.2017