EVS-EN 50527-1:2016

Elektromagnetväljade mõju hindamine aktiivseid implanteeritavaid meditsiiniseadmeid kandvate töötajate korral. Osa 1: Üldine

Üldinfo

Kehtiv alates 03.01.2017
Alusdokumendid
EN 50527-1:2016
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
03.01.2017
Põhitekst
07.06.2010
Põhitekst
This European Standard provides a procedure to assess the risk to workers bearing one or more active implantable medical devices from exposure to electric, magnetic and electromagnetic fields at a workplace. It describes how a general risk assessment should be performed and determines whether it is necessary to carry out a detailed risk assessment.
NOTE 1  This European Standard does not cover indirect effects caused by non active implants.
NOTE 2  The risk of human exposure to EMF considered is only due to malfunctioning of AIMD. Possibilities of AIMD contribution to the risk, e.g. local modification of the distribution of EMF produced by external source or production of own EMF, are covered by the respective product standards for the AIMD.
Based on specific workplace standards it can be determined whether preventive measures/actions need to be taken to comply with the provisions of Directive 2013/35/EU. The work situation covered is considered to be under normal working conditions including normal operation, maintenance, cleaning and other situations being part of the normal work.
The frequencies covered are from 0 Hz to 300 GHz.
The European Parliament and Council Directive 2013/35/EU will be transposed into national legislation in all the EU member countries. It is recommended that users of this standard consult the national legislation related to this transposition in order to identify the national regulations and requirements. These national regulations and requirements may have additional requirements that are not covered by this standard and take precedence.
NOTE 3  Performance requirements with respect to active implantable medical devices are excluded from the Scope of this standard. These are defined in the relevant particular standards for active implantable medical devices.
The risk assessment described in this standard is only required if an AIMD-Employee is present.
Active Implantable Medical Devices (AIMDs) are regulated by Directive 90/385/EEC and the amendments to it.
NOTE 4  Product standards EN 45502-1 and of the EN 45502-2-X series describe the product requirements for different kinds of AIMDs. Different kinds of AIMDs are e.g. pacemaker (EN 45502-2-1), implantable cardioverter defibrillators (EN 45502-2-2), cochlear implants (EN 45502-2-3), implantable neurostimulators (ISO 14708-3), implantable infusion pumps (ISO 14708-4).
In situations where the risk assessment following this standard does not lead to a conclusion, complementary provisions for the assessment of workers exposure for different kinds of AIMDs are given in particular standards for these specific AIMDs (see Figure 1).
(...)
Figure 1 - Structure of the EN 50527 family of standards

Nõutud väljad on tähistatud *

*
*
*
PDF
24,40 € koos KM-ga
Paber
24,40 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 50527-2-1:2016

Elektromagnetväljade mõju hindamine aktiivseid implanteeritavaid meditsiiniseadmeid kandvate töötajate korral. Osa 2: Erinõuded südamestimulaatoriga töötajate korral
Uusim versioon Kehtiv alates 03.01.2017
Põhitekst

EVS-EN 50527-2-2:2018

Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-2: Specific assessment for workers with cardioverter defibrillators (ICDs)
Uusim versioon Kehtiv alates 16.05.2018
Põhitekst + muudatus

EVS-EN 60601-1-2:2015+A1:2021

Elektrilised meditsiiniseadmed. Osa 1-2: Üldnõuded esmasele ohutusele ja olulistele toimimisnäitajatele. Kollateraalstandard: Elektromagnetiline ühilduvus. Nõuded ja katsetused
Uusim versioon Kehtiv alates 01.04.2021
Põhitekst

EVS-EN 50527-2-3:2021

Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-3: Specific assessment for workers with implantable neurostimulators
Uusim versioon Kehtiv alates 15.11.2021