EVS-EN 50174-3:2013/A1:2017

Information technology - Cabling installation - Part 3: Installation planning and practices outside buildings

Üldinfo

Kehtiv alates 02.06.2017
Alusdokumendid
EN 50174-3:2013/A1:2017
Tegevusala (ICS grupid)
35.110 Võrk
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
02.06.2017
Muudatus
14.11.2013
Põhitekst
This European Standard specifies requirements and provides recommendations for the following aspects of information technology cabling:
a)  planning;
b)  installation practice.
This European Standard is applicable to all types of information technology cabling outside buildings including generic cabling systems designed in accordance with EN 50173 series. The requirements and recommendations of this European Standard may be applied to cabling that is defined as part of the building.
The requirements and recommendations of Clauses 4, 5 and 6 of this European Standard are subject to any site-specific requirements and recommendations of Clause 7.
The planning of the pathway systems, spaces and structures within the core and access network cabling as described in Figure 2 that are owned by access providers is excluded except for requirements and recommendations that provide basic safety, function and environmental objectives for mechanical, ingress and climatic characteristics (i.e. excluding pathway dimensions, distribution of spaces and similar constraints based on specific transmission methods).
The installation practices applicable to all cabling installation methods are included by the provision of the necessary planning requirements and recommendations associated with each one with the exception of information technology cabling installed:
–  around or within aerial power supply or associated earth conductors;
–  on infrastructures carrying power supplies in excess of AC/DC 25 kV.
This European Standard:
1)  details the considerations for satisfactory installation and operation of information technology cabling;
2)  excludes specific requirements applicable to other cabling systems (e.g. power supply cabling); however, it takes account of the effects other cabling systems may have on the installation of information technology cabling (and vice versa) and gives general advice;
3)  excludes those aspects of installation associated with the transmission of signals in free space between transmitters, receivers or their associated antenna systems (e.g. wireless, radio, microwave or satellite).
This European Standard is applicable to certain hazardous environments. It does not exclude additional requirements which are applicable in particular circumstances, defined by e.g. electricity supply and electrified railways.
The requirements within this European Standard do not cover any additional requirements for the information technology cables installed in hazardous or stressful environments e.g. electricity supply and electric railway locations (see Clause 7).

Nõutud väljad on tähistatud *

*
*
*
PDF
15,86 € koos KM-ga
Paber
15,86 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 50174-2:2018

Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings
Uusim versioon Kehtiv alates 16.07.2018
Põhitekst

EVS-EN 50174-3:2013

Infotehnoloogia. Juhtmete paigaldamine. Osa 3: Väljaspool hooneid asuvate süsteemide planeerimine ja paigaldamine
Uusim versioon Kehtiv alates 14.11.2013
Põhitekst

EVS-EN 50174-1:2018

Information technology - Cabling installation - Part 1: Installation specification and quality assurance
Kehtiv alates 16.07.2018
Põhitekst + muudatus

EVS-EN 50174-1:2018+A1:2020

Information technology - Cabling installation - Part 1: Installation specification and quality assurance
Uusim versioon Kehtiv alates 03.08.2020