EVS-EN 14620-4:2006

Design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between -5 °C and -165 °C - Part 4: Insulation components

Üldinfo

Kehtiv alates 06.11.2006
Alusdokumendid
EN 14620-4:2006
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
Põhitekst
prEN 14620-4
06.11.2006
Põhitekst
This European Standard specifies the requirements for materials, design and installation of the insulation of refrigerated liquefied gas (RLG) storage tanks. RLG storage tanks store liquefied gas with a low boiling point, i.e. below normal ambient temperature. The concept of storing such products in liquid form and in non-pressurized tanks therefore depends on the combination of latent heat of vaporization and thermal insulation. Consequently thermal insulation for RLG storage tanks is not an ancillary part of the containment system (as for most ambient atmospheric hydrocarbon tanks) but it is an essential component and the storage tank cannot operate without a properly designed, installed and maintained insulation system.

Nõutud väljad on tähistatud *

*
*
*
PDF
24,40 € koos KM-ga
Paber
24,40 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 14620-1:2006

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 C and -165 C - Part 1: General
Kehtetu alates 03.06.2024
Põhitekst

EVS-EN 14620-2:2006

Design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between -5 °C and -165 °C - Part 2: Metallic components
Uusim versioon Kehtiv alates 06.11.2006
Põhitekst

EVS-EN 14620-3:2006

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 C and -165 C - Part 3: Concrete components
Uusim versioon Kehtiv alates 06.11.2006
Põhitekst

EVS-EN 14620-5:2006

Design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between -5°C and -165°C - Part 5: Testing, drying, purging and cool-down
Uusim versioon Kehtiv alates 06.11.2006