Skip to main content
Back

EVS-EN ISO 16140-4:2020+A1:2024

Microbiology of the food chain - Method validation - Part 4: Protocol for method validation in a single laboratory (ISO 16140-4:2020 + ISO 16140-4:2020/Amd 1:2024)

General information

Valid from 15.11.2024
Base Documents
ISO 16140-4:2020; EN ISO 16140-4:2020; ISO 16140-4:2020/Amd 1:2024; EN ISO 16140-4:2020/A1:2024
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.11.2024
Main + amendment
01.10.2024
Amendment
15.09.2020
Main
This document specifies the general principles and the technical protocols for single-laboratory validation of methods for microbiology in the food chain. The protocols in this document only validate the method for the laboratory conducting the study.
This document is applicable to single-laboratory validation of:
—  methods used in the analysis (detection or quantification) of microorganisms in:
—  products intended for human consumption;
—  products intended for animal feeding;
—  environmental samples in the area of food and feed production, handling;
—  samples from the primary production stage;
—  methods for the confirmation or typing of microorganisms. This validation will replace only the confirmation or typing procedure of a specified method (see Annex G).
This document is, in particular, applicable to bacteria and fungi. Some clauses can be applicable to other (micro)organisms or their metabolites, to be determined on a case-by-case basis.
Single-laboratory validation is required if an interlaboratory validation in accordance with ISO 16140-2 is not appropriate. Possible applications are:
—  validation of an in-house method;
—  method evaluation study in the validation process of a reference method in accordance with ISO 17468;
—  extension of the scope of an ISO 16140-2 validated method, e.g. category extension or test portion size;
—  modifications of existing methods.
Single-laboratory validation is the second step in the standardization of a reference method (see ISO 17468). It is only applicable to methods that are fully specified with regard to all relevant parameters (including tolerances on temperatures and specifications on culture media) and that have already been optimized.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 16140-1:2016

Microbiology of the food chain - Method validation - Part 1: Vocabulary (ISO 16140-1:2016)
Newest version Valid from 03.08.2016
Main

EVS-EN ISO 16140-5:2020

Microbiology of the food chain - Method validation - Part 5: Protocol for factorial interlaboratory validation for non-proprietary methods (ISO 16140-5:2020)
Newest version Valid from 15.09.2020
Main + amendment

EVS-EN ISO 11607-1:2020+A11+A1:2023

Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems (ISO 11607-1:2019 + ISO 11607-1:2019/Amd 1:2023)
Newest version Valid from 15.11.2023