Skip to main content
Back

EVS-EN 89:2015

Gas-fired storage water heaters for the production of domestic hot water

General information

Valid from 08.06.2015
Base Documents
EN 89:2015
Directives or regulations
None

Standard history

Status
Date
Type
Name
08.06.2015
Main
04.01.2007
Amendment
08.12.2006
Amendment
01.02.2001
Amendment
01.04.2000
Main
This European Standard defines the specifications and test methods for the construction, safety, rational use of energy and fitness for purpose, environment and classification and marking of gas-fired storage water heaters for domestic hot water uses, hereafter called "appliance". This standard applies to appliances : - of types B11, B11BS, C11, C12, C13, C21, C31, , C32, C33, C42, C43, C51,C52, C53, C62, C63, C72, C73, C81 connected to an individual flue duct, C82 and C83 ; - fitted with atmospheric burners ; - using one or more combustible gases corresponding to the three gas families and the pressures indicated in EN 437 ; - of nominal heat input not exceeding 150 kW (net calorific value) ; - using or not the water condensation heat in the combustion products ; - fitted with electrically operated mechanical flue dampers that are positioned downstream of the heat exchanger and tested as an integral part of the water heater. - appliances whether subject to the water mains pressure or open-circuit. This standard does not contain all the requirements necessary for : - appliances fitted with a fan on the combustion circuit ; - appliances intended to be connected to a mechanical means of evacuating the combustion products ; - appliances which fulfill a dual role of space heating and heating water for domestic hot water use ; - appliances with a combustion products discharge safety device other than that for type B11BS appliances; This standard does not contain all the necessary requirements to make it applicable to appliances with a variable combustion air flow rate.

Required fields are indicated with *

*
*
*
PDF
46.36 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 161:2011+A3:2013

Automatic shut-off valves for gas burners and gas appliances
Withdrawn from 01.11.2022
Main

EVS-EN 16129:2013

Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixture
Newest version Valid from 05.08.2013
Main

EVS-EN 13611:2015

Safety and control devices for burners and appliances burning gaseous and/or liquid fuels - General requirements
Withdrawn from 15.04.2019
Main

EVS-EN 15502-2-2:2014

Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances
Withdrawn from 01.08.2024