Skip to main content

Infoteenus

71 KEEMILINE TEHNOLOOGIA
Uued standardid
ISO 20263:2024
Microbeam analysis — Analytical electron microscopy — Method for the determination of interface position in the cross-sectional image of the layered materials
Käsitlusala: This document specifies a procedure for the determination of the averaged interface position between two different layered materials recorded in the cross-sectional image of the multi-layered material. This document does not apply for determining the simulated interface of the multi-layered materials expected through the multi-slice simulation (MSS) method.
This document is applicable to the cross-sectional images of multi-layered materials recorded using a transmission electron microscope (TEM) or a scanning transmission electron microscope (STEM) and cross-sectional elemental mapping images using an energy dispersive X-ray spectrometer (EDS) or an electron energy loss spectrometer (EELS). This document is also applicable to digitized images recorded on an image sensor built into a digital camera, a digital memory set in the PC or an imaging plate, where the digitalized image is obtained by converting an analogue image recorded on photographic film using an image scanner.
Alusdokumendid:
Asendab: ISO 20263:2017
Asendatud standardid
ISO 20263:2017
Microbeam analysis -- Analytical electron microscopy -- Method for the determination of interface position in the cross-sectional image of the layered materials
Käsitlusala: ISO 20263:2017 specifies a procedure for the determination of averaged interface position between two different layered materials recorded in the cross-sectional image of the multi-layered materials. It is not intended to determine the simulated interface of the multi-layered materials expected through the multi-slice simulation (MSS) method. This document is applicable to the cross-sectional images of the multi-layered materials recorded by using a transmission electron microscope (TEM) or a scanning transmission electron microscope (STEM) and the cross-sectional elemental mapping images by using an energy dispersive X-ray spectrometer (EDS) or an electron energy loss spectrometer (EELS). This document is also applicable to the digitized image recorded on an image sensor built into a digital camera, a digital memory set in the PC or an imaging plate and the digitalized image converted from an analogue image recorded on the photographic film by an image scanner.
Alusdokumendid:
Asendatud: ISO 20263:2024
Kavandid