Skip to main content
Back
NEW

prEN ISO 18127

Water quality - Determination of adsorbable organically bound fluorine, chlorine, bromine and iodine (AOF, AOCl, AOBr, AOI) - Method using combustion and subsequent ion chromatographic measurement (ISO/DIS 18127:2024)

General information

Draft
Base Documents
ISO/DIS 18127; prEN ISO 18127
Directives or regulations
None
You can view draft standards in the Commenting portal🡭.

Standard history

Status
Date
Type
Name
This dcoument specifies a method for the determination of fluoro-, chloro-, bromo- and iodo-organic compounds (AOF, AOCl, AOBr, AOI). Due to the high solubility of AgF in water the scope of ISO 9562 is restricted to Cl-, Br- and I-organic compounds (AOX, calculated as chlorine) because of the applied argentometric detection. The PN follows the proven AOX ISO 9562 method: adsorption of organohalogen
compounds on activated carbon, oxidative combustion at 1000 °C with following alterations: constant water feed during combustion (hydropyrolysis), absorption of combustion gases in water, halide specific detection using ionchromatography. The method is applicable for the determination of
2 µg/l AOF, expressed as F
10 µg/l AOCl, expressed as Cl
1 µg/l AOBr, expressed as Br
1 µg/l AOI, expressed as I.
Samples for determination of AOF are treated differently than samples for the determination of AOCl,
AOBr and AOI.
- Samples for determination of AOF are not acidified. The adsorption takes place under unchanged pH
conditions. Washing is also performed with a neutral washing solution.
- Samples for the determination of AOCl, AOBr and AOI are adjusted to a pH value 2 with nitric acid,
the adsorption and washing take place in a nitric acid environment.

Required fields are indicated with *

*
*
*
Standard monitoring