ISO 28540:2011

Water quality -- Determination of 16 polycyclic aromatic hydrocarbons (PAH) in water -- Method using gas chromatography with mass spectrometric detection (GC-MS)

General information

Valid from 21.07.2011
Directives or regulations
None

Standard history

Status
Date
Type
Name
21.07.2011
Main
ISO 28540:2011 specifies a method for the determination of at least 16 selected PAH (see Table 1) in drinking water and ground water in mass concentrations above 0,005 �g/l and surface water in mass concentrations above 0,01 �g/l (for each individual compound).
ISO 28540:2011 can be used for samples containing up to 150 mg/l of suspended matter.
This method is, with some modification, also suitable for the analysis of waste water. It is possible that this method is applicable to other PAH, provided the method is validated for each case.

Required fields are indicated with *

*
*
*
PDF
197.98 € incl tax
Paper
197.98 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 15527:2008

Characterization of waste - Determination of polycyclic aromatic hydrocarbons (PAH) in waste using gas chromatography mass spectrometry (GC/MS)
Withdrawn from 01.03.2022
Main

EVS-EN ISO 17294-2:2016

Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016)
Withdrawn from 01.11.2023
Main

ISO 10390:2005

Soil quality -- Determination of pH
Withdrawn from 06.04.2021
Main

EVS-EN ISO 22854:2016

Liquid petroleum products - Determination of hydrocarbon types and oxygenates in automotive-motor gasoline and in ethanol (E85) automotive fuel - Multidimensional gas chromatography method (ISO 22854:2016)
Withdrawn from 01.12.2021