Skip to main content
Back

EVS-EN 16750:2017+A1:2020

Fixed firefighting systems - Oxygen reduction systems - Design, installation, planning and maintenance

General information

Valid from 01.09.2020
Base Documents
EN 16750:2017+A1:2020
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.09.2020
Main + amendment
18.09.2017
Main
This European standard specifies oxygen reduction systems that are used as fire prevention systems by creating an atmosphere in an area which is having a lower permanent oxygen concentration as in ambient conditions. The level of oxygen reduction is defined by the individual risks of these areas (see Annex A). Oxygen reduction is achieved by technical systems which are providing a flux of air containing a reduced concentration of oxygen.
This European standard specifies minimum requirements and defines the specifications governing the design, installation and maintenance of fixed oxygen reduction systems with oxygen reduced air in buildings and industrial production plants. The standard also applies to the extension and modification of existing systems.
This European standard applies to oxygen reduction systems using nitrogen which are designed for continual oxygen reduction in enclosed spaces.
NOTE  Nitrogen is today the most suitable gas to be used for oxygen reduction. For other gases this European standard can be used as basis.
This European standard does not apply to oxygen reduction systems that use water mist or combustion gases.
The European standard does not apply to:
-  explosion suppression systems;
-  explosion prevention systems;
-  fire extinguishing systems using gaseous extinguishing agents;
-  inertization of portable containers;
-  systems in which oxygen levels are reduced for reasons other than fire prevention (e.g. steel processing in the presence of inert gas to avoid the formation of oxide film);
-  inerting required during repair work on systems or equipment (e.g. welding) in order to eliminate the risk of fire or explosion.
In addition to the conditions for the actual oxygen reduction system and its individual components this European standard also covers certain structural specifications for the protected area.
The space protected by an oxygen reduction system is a controlled and continuously monitored indoor climate for extended occupation. This standard does not cover unventilated confined spaces that may contain hazardous gases.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 12845:2015+A1:2020

Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance
Newest version Valid from 15.05.2020
Main + amendment

EVS-EN 50131-1:2006+A1+A2+A3:2020

Alarm systems - Intrusion and hold-up systems - Part 1: System requirements
Newest version Valid from 17.08.2020
Main

EVS-EN IEC 62676-5:2018

Video surveillance systems for use in security applications - Part 5: Data specifications and image quality performance for camera devices
Newest version Valid from 16.08.2018
Main

EVS-EN 62676-4:2015

Video surveillance systems for use in security applications - Part 4: Application guidelines
Newest version Valid from 07.05.2015