Skip to main content
Back

EVS-EN 15269-11:2018

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 11: Fire resistance for operable fabric curtains (Corrected version 03.2019)

General information

Valid from 03.05.2018
Base Documents
EN 15269-11:2018+AC:2019
Directives or regulations
None

Standard history

Status
Date
Type
Name
03.05.2018
Main + corrigendum
This document covers vertically mounted types of manual or powered, operable fabric curtain assemblies with downward closing operation. Curtain systems are different from (are separated from) door systems due to their not rigid closure element typically made of thin walled materials as for instance woven or knitted fabrics and foils. These closure elements are not able to carry significant loads normal to their surface by their bending stiffness. In other words: curtain systems are separated from door systems because they can only conduct pulling forces by tensile stress in plane to their surface. Pushing forces are not conducted in plane to their surface.
This document establishes the methodology for extending the application of test results obtained from test(s) conducted in accordance with the EN 1634-1 test method for shutters.
Subject to the completion of the appropriate test or tests selected from those identified in Clause 4, the extended application may cover all or some of the following non-exhaustive list of examples:
-  uninsulated (E), radiation (EW) or insulated (EI1 or EI2) classifications;
-  coiling mechanisms;
-  wall/ceiling fixed elements;
-  items of building hardware;
-  decorative finishes;
-  intumescent, draught or acoustic seals;
-  alternative supporting construction(s).

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + corrigendum

EVS-EN 15269-1:2019

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements
Newest version Valid from 02.07.2019
Main + amendment

EVS-EN 1366-12:2014+A1:2019

Fire resistance tests for service installations - Part 12: Non-mechanical fire barrier for ventilation ductwork
Newest version Valid from 15.11.2019
Main

EVS-EN 1363-1:2020

Fire resistance tests - Part 1: General requirements
Newest version Valid from 04.05.2020
Main

EVS-EN 15254-7:2018

Extended application of results from fire resistance tests - Non-loadbearing ceilings - Part 7: Metal sandwich panel construction
Newest version Valid from 03.05.2018