Skip to main content
Back

EVS-EN 1634-3:2004

Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies

General information

Valid from 05.01.2005
Base Documents
EN 1634-3:2004; EN 1634-3:2004/AC:2006
Directives or regulations
None

Standard history

Status
Date
Type
Name
05.01.2005
Main + corrigendum
This Part of EN 1634 specifies a method for determining the leakage of cold and warm smoke from one side of a door assembly to the other under the specified test conditions. The test can be applied
to door and shutter assemblies of different types intended for purposes of controlling the passage of smoke in case of fire. This test can also be applied to lift landing doors and conveyor system doors and shutters. The principle of the test is explained briefly in annex A.

Required fields are indicated with *

*
*
*
PDF
19.52 € incl tax
Paper
19.52 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 1634-1:2014+A1:2018

Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows
Newest version Valid from 01.02.2018
Main

EVS-EN 1634-1:2014

Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows
Withdrawn from 01.02.2018
Main

EVS-EN 15269-2:2012

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 2: Fire resistance of hinged and pivoted steel doorsets
Newest version Valid from 06.11.2012
Main

EVS-EN 15269-20:2009

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metalframed glazed doorsets
Withdrawn from 02.11.2020