Skip to main content
Back

ISO 15877-2:2009

Plastics piping systems for hot and cold water installations -- Chlorinated poly(vinyl chloride) (PVC-C) -- Part 2: Pipes

General information

Valid from 05.03.2009
Directives or regulations
None

Standard history

Status
Date
Type
Name
07.12.2020
Amendment
20.10.2010
Amendment
05.03.2009
Main
ISO 15877-2:2009 specifies the requirements of pipes made from chlorinated poly(vinyl chloride) (PVC-C) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application.
ISO 15877-2:2009 covers a range of service conditions (application classes), design pressures and pipe series. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1:2009. ISO 15877-2:2009 also specifies the test parameters for the test methods to which it refers.
In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes, their joints and joints with components of PVC-C, other plastics and non-plastics materials intended to be used for hot and cold water installations.