Skip to main content
Back

IEC 61000-6-3:2006

Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments

General information

Withdrawn from 30.07.2020
Directives or regulations
None

Standard history

Status
Date
Type
Name
30.07.2020
Main
17.07.2006
Main
This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments.

Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified.

This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists.

This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source, which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below.

The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations that are included:

- residential properties, for example houses, apartments;

- retail outlets, for example shops, supermarkets;

- business premises, for example offices, banks;

- areas of public entertainment, for example cinemas, public bars, dance halls;

- outdoor locations, for example petrol stations, car parks, amusement and sports centres;

- light-industrial locations, for example workshops, laboratories, service centres.

Locations that are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial.

The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances.

The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in residential, commercial and light-industrial locations do not exceed a level which could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements.

Requirements are specified for each port considered.

Required fields are indicated with *

*
*
*
PDF
104.90 € incl tax
Paper
104.90 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

IEC 61000-6-2:2005

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
Withdrawn from 10.08.2016
Main

EVS-EN 61984:2009

Connectors - Safety requirements and tests
Newest version Valid from 07.08.2009
Main

IEC 61000-4-2:2008

Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
Newest version Valid from 09.12.2008
Main

IEC 61439-7:2018

Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
Withdrawn from 07.07.2022