Skip to main content
Back

IEC 61000-3-12:2011

Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

General information

Valid from 12.05.2011
Directives or regulations
None

Standard history

Status
Date
Type
Name
04.06.2021
Amendment
12.05.2011
Main
IEC 61000-3-12:2011 deals with the limitation of harmonic currents injected into the public supply system. The limits given in this International Standard are applicable to electrical and electronic equipment with a rated input current exceeding 16 A and up to and including 75 A per phase, intended to be connected to public low-voltage a.c. distribution systems of the following types:
- nominal voltage up to 240 V, single-phase, two or three wires;
- nominal voltage up to 690 V, three-phase, three or four wires;
- nominal frequency 50 Hz or 60 Hz. Other distribution systems are excluded. The limits given in this edition apply to equipment when connected to 230/400 V, 50 Hz systems. This standard applies to equipment intended to be connected to low-voltage systems interfacing with the public supply at the low-voltage level. It does not apply to equipment intended to be connected only to private low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. This standard defines:
a) requirements and emission limits for equipment;
b) methods for type tests and simulations. Tests according to this International Standard are type tests of complete pieces of equipment. Conformity with this standard can also be determined by validated simulations. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The significant technical changes with respect to the previous edition are:
- the replacement of the reference fundamental current I1 by the reference current Iref for the calculation of emission limits;
- a new added table of current emission limits (Table 5);
- a new added annex (Annex A) to define test conditions for some types of equipment;
- Deletion of the former Annexes B (Approximate interpolation formulas) and D (Information on the PWHD factor).

Required fields are indicated with *

*
*
*
PDF
249.11 € incl tax
Paper
249.11 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

IEC 61000-3-12:2011/AMD1:2021

Amendment 1 - Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
Newest version Valid from 04.06.2021
Main + amendment

EVS-EN IEC 61000-3-2:2019+A1:2021

Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) (IEC 61000-3-2:2018 + IEC 61000-3-2:2018/A1:2020)
Valid from 01.06.2021
Main

EVS-EN 61000-1-2:2016

Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena
Newest version Valid from 01.11.2016
Main

EVS-EN IEC 61000-6-2:2019

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments (IEC 61000-6-2:2016)
Newest version Valid from 01.03.2019