Skip to main content
Back

EVS-EN ISO 9308-2:2014

Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method (ISO 9308-2:2012)

General information

Valid from 05.06.2014
Base Documents
ISO 9308-2:2012; EN ISO 9308-2:2014
Directives or regulations
None

Standard history

Status
Date
Type
Name
05.06.2014
Main
ISO 9308-2:2012 specifies a method for the enumeration of E. coli and coliform bacteria in water. The method is based on the growth of target organisms in a liquid medium and calculation of the "Most Probable Number" (MPN) of organisms by reference to MPN tables. This method can be applied to all types of water, including those containing an appreciable amount of suspended matter and high background counts of heterotrophic bacteria. However it must not be used for the enumeration of coliform bacteria in marine water. When using for the enumeration of E. coli in marine waters, a 1→10 dilution in sterile water is typically required, although the method has been shown to work well with some marine waters that have a lower than normal concentration of salts. In the absence of data to support the use of the method without dilution, a 1→10 dilution is used.
This method relies upon the detection of E. coli based upon expression of the enzyme b‑D‑glucuronidase and consequently does not detect many of the enterohaemorhagic strains of E. coli, which do not typically express this enzyme. Additionally, there are a small number of other E. coli strains that do not express b‑D‑glucuronidase.
The choice of tests used in the detection and confirmation of the coliform group of bacteria, including E. coli, can be regarded as part of a continuous sequence. The extent of confirmation with a particular sample depends partly on the nature of the water and partly on the reasons for the examination. The test described in ISO 9308-2:2012 provides a confirmed result with no requirement for further confirmation of positive wells.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 9308-1:2014

Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora (ISO 9308-1:2014)
Valid from 07.11.2014
Main

EVS-EN ISO 7899-2:2002

Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
Newest version Valid from 01.06.2002
Main + amendment

EVS-EN ISO 7218:2008+A1:2013

Microbiology of food and animal feeding stuffs - General requirements and guidance for microbiological examinations
Withdrawn from 01.08.2024
Main

EVS-EN ISO 19458:2006

Water quality - Sampling for microbiological analysis
Newest version Valid from 06.10.2006