EVS-EN ISO 81060-3:2023

Non-invasive sphygmomanometers - Part 3: Clinical investigation of continuous automated measurement type (ISO 81060-3:2022)

General information

Valid from 17.01.2023
Base Documents
ISO 81060-3:2022; EN ISO 81060-3:2023
Directives or regulations
None

Standard history

Status
Date
Type
Name
17.01.2023
Main
This document specifies the requirements and methods for the clinical investigation of continuous automated non-invasive sphygmomanometers used for the measurement of the blood pressure of a patient.
This document does not cover usability aspects such as the form and manner of the data display or output. This document does not specify a numerical threshold on the minimum output period. A continuous automated non-invasive sphygmomanometer providing blood pressure parameters (e.g., systolic blood pressure, diastolic blood pressure or mean arterial pressure) with an output period considerably larger than 30 s is not typically considered a continuous automated non-invasive sphygmomanometer.
This document covers both trending continuous automated non-invasive sphygmomanometers and absolute accuracy continuous automated non-invasive sphygmomanometers and focuses solely on requirements for the clinical investigation. Representation of output is not covered by this document.
NOTE 1    IEC 62366-1 provides requirements on the application of usability engineering to medical devices. The usability engineering process can be used to clarify for the intended user whether the displayed data concerns absolute accurate values or trending values.
The requirements and methods for the clinical investigation of continuous automated non-invasive sphygmomanometers provided in this document are applicable to any subject population, and any condition of use of the continuous automated non-invasive sphygmomanometers.
NOTE 2    Subject populations can, for example, be represented by age or weight ranges.
NOTE 3    This document does not provide a method to assess the effect of artefacts during the clinical investigation (e.g. motion artefacts induced by the movement of the subject or the movement of the platform supporting the subject).
This document specifies additional disclosure requirements for the accompanying documents of continuous automated non-invasive sphygmomanometers that have undergone clinical investigation according to this document.
This document is not applicable to:
—    the clinical investigation of a non-automated sphygmomanometer as given in ISO 81060-1,
—    the clinical investigation of an intermittent automated non-invasive sphygmomanometer as given in ISO 81060-2,
—    an automated non-invasive sphygmomanometer as given in IEC 80601-2-30, or
—    invasive blood pressure monitoring equipment as given in IEC 60601‑2‑34.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO/IEEE 11073-10407:2022

Health informatics - Device interoperability - Part 10407: Personal health device communication - Device specialization - Blood pressure monitor (ISO/IEEE 11073-10407:2022)
Newest version Valid from 30.12.2022
Main + amendment

EVS-EN 60601-1:2006+A1+A12+A2:2021

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005, modified + A1:2013 + A12:2014 + IEC 60601-1:2005/A2:2020)
Valid from 01.11.2021
Amendment

EVS-EN ISO 81060-2:2019/A1:2020

Non-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type - Amendment 1 (ISO 81060-2:2018/Amd 1:2020)
Valid from 02.10.2020
Main + amendment

EVS-EN 60601-1-2:2015+A1:2021

Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests (IEC 60601-1-2:2014 + IEC 60601-1-2:2014/A1:2020)
Newest version Valid from 01.04.2021