EVS-EN ISO 25539-3:2024

Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters (ISO 25539-3:2024)

General information

Valid from 01.11.2024
Base Documents
ISO 25539-3:2024; EN ISO 25539-3:2024
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.11.2024
Main
04.01.2012
Main
This document specifies the requirements for the evaluation of vena cava filter systems (filters and delivery systems) and the requirements with respect to nomenclature, design attributes and information supplied by the manufacturer. Guidance for the development of in vitro test methods is included in Annex D. This document is intended to be used in conjunction with ISO 14630, which specifies general requirements for the performance of non-active surgical implants.
NOTE 1       Due to the variations in the design of implants covered by this document, and in some cases due to the emergence of novel types of such implants, acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, a revision of this document will be necessary.
This document is applicable to vena cava filters intended to prevent symptomatic pulmonary embolism by capturing blood clots in the inferior vena cava (IVC). While this document can be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address the use of filters in other implantation sites.
This document is also applicable to permanent filters together with their associated delivery systems, optional filters that can be retrieved and their associated retrieval systems, and convertible filters and their associated conversion systems. While this document can be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.
This document is not applicable to
—           temporary filters (e.g. tethered) that need to be removed after a defined period of time,
—           issues associated with viable tissues and non-viable biological materials, and
—           procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.
Although absorbable filters and filters with absorbable coatings are within the scope of this document, this document is not comprehensive with respect to the absorbable properties of these devices.
NOTE 2       Absorbable implants are covered in ISO/TS 17137.
Although coated filters and coated filter systems are within the scope of this document, this document is not comprehensive with respect to coatings.
NOTE 3       Vascular device-drug combination products are covered in ISO 12417-1 and some coating properties are covered in ISO 25539-4.

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 10993-12:2021

Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2021)
Newest version Valid from 01.07.2021
Main + amendment

EVS-EN ISO 11607-1:2020+A11+A1:2023

Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems (ISO 11607-1:2019 + ISO 11607-1:2019/Amd 1:2023)
Newest version Valid from 15.11.2023
Main + amendment

EVS-EN ISO 11607-2:2020+A11+A1:2023

Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes (ISO 11607-2:2019 + ISO 11607-2:2019/Amd 1:2023)
Newest version Valid from 15.11.2023
Main

EVS-EN ISO 10993-17:2023

Biological evaluation of medical devices - Part 17: Toxicological risk assessment of medical device constituents (ISO 10993-17:2023)
Newest version Valid from 01.12.2023