This document specifies a method for the enumeration of Pseudomonas aeruginosa in water. The method is based on the growth of target organisms in a liquid medium and calculation of the most probable number (MPN) of organisms by reference to MPN tables.
This document is applicable to a range of types of water. For example, hospital waters, drinking water and non‐carbonated bottled waters intended for human consumption, groundwater, swimming pool and spa pool waters including those containing high background counts of heterotrophic bacteria.
This document does not apply to carbonated bottled waters, flavoured bottle waters, cooling tower waters or marine waters, for which the method has not been validated. These waters are, therefore, outside the scope of this document. Laboratories can employ the method presented in this document for these matrices by undertaking appropriate validation of performance of this method prior to use.
The test is based on a bacterial enzyme detection technology that signals the presence of P. aeruginosa through the hydrolysis of a 7‐amino‐4‐methylcoumarin aminopeptidase substrate present in a special reagent. P. aeruginosa cells rapidly grow and reproduce using the rich supply of amino acids, vitamins
and other nutrients present in the reagent. Actively growing strains of P. aeruginosa have an enzyme that cleaves the 7‐amido‐coumarin aminopeptidase substrate releasing a product which fluoresces under ultraviolet (UV) light. The test described in this document provides a confirmed result within 24 h with no requirement for further confirmation of positive wells.

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 7899-2:2002

Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
Newest version Valid from 01.06.2002
Main

EVS-EN ISO 6222:2001

Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium (ISO 6222:1999)
Newest version Valid from 01.10.2001
Main

EVS-EN ISO 6888-1:2021

Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 1: Method using Baird-Parker agar medium (ISO 6888-1:2021)
Valid from 16.09.2021
Main

EVS-EN ISO 19458:2006

Water quality - Sampling for microbiological analysis
Newest version Valid from 06.10.2006