Skip to main content
Back

EVS-EN ISO 10993-13:2010

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices

General information

Valid from 04.10.2010
Base Documents
ISO 10993-13:2010; EN ISO 10993-13:2010
Directives or regulations
None

Standard history

Status
Date
Type
Name
This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize  in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only non-resorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity. NOTE An informative text discussing environmental stress cracking (ESC) of polymers is included as a potential aid to the design of degradation studies (see Annex B). The biological activity of the debris and soluble degradation products is not addressed in this part of ISO 10993, but should be evaluated according to the principles of ISO 10993-1, ISO 10993-16 and ISO 10993-17. Because of the wide range of polymeric materials used in medical devices, no specific analytical techniques are identified or given preference. No specific requirements for acceptable levels of degradation products are provided in this part of ISO 10993.

Required fields are indicated with *

*
*
*
PDF
19.52 € incl tax
Paper
19.52 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 10993-5:2009

Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity
Newest version Valid from 07.08.2009
Main

EVS-EN ISO 10993-3:2014

Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2014)
Newest version Valid from 07.11.2014
Main

EVS-EN ISO 10993-11:2018

Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2017)
Newest version Valid from 18.06.2018
Main

EVS-EN ISO 10993-17:2009

Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances
Withdrawn from 01.12.2023