EVS-EN IEC 61753-1:2018

Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance

General information

Valid from 16.11.2018
Base Documents
IEC 61753-1:2018; EN IEC 61753-1:2018
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.09.2020
Amendment
02.07.2019
Corrigendum
16.11.2018
Main
08.01.2008
Main
IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors;
b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests;
c) addition of Category I (Industrial);
d) temperature ranges added  (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for “heat dissipation”);
e) the height of category A changed from 3 m to ground level (0 m);
f) the lower level height of category G environment changed from ground level (0 m) to –1 m below ground level. Upper level remains at 3 m above ground level;
g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors;
h) test severity of "Mating durability" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules;
i) test severity of "Change of temperature" test for connectors and passive optical components in category I is reduced from 20 cycles to 12 cycles (harmonized with connectors and components from other categories);
j) test severity of "Flexing of strain relief" test for connectors in categories C, OP and OP+ is reduced to 50 cycles;
k) test severities of "Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures" test for all enclosures is reduced to 5 cycles;
l) test severities of "Change of temperature" test for all protective housings in categories C, A, G and S is reduced from 20 cycles to 12 cycles (harmonized with connectors and components);
m) test severities of "Resistance to solvents and contaminating fluids" test for closures in categories G and S changed – kerosene is removed, diesel oil exposure reduced to 1 h immersion and 24 h drying at room temperature;
n) sealing performance criteria of sealed closures for categories G and A are reduced to 20 kPa overpressure.
o) the change in attenuation criterion for connectors has changed from peak-to-peak into a +/- deviation from the original value of the transmitted power at the start of the test (harmonized with the change in attenuation criterion

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 60794-1-21:2015

Optical fibre cables - Part 1-21: Generic specification - Basic optical cable test procedures - Mechanical tests methods
Withdrawn from 15.10.2024
Main

EVS-EN 60794-2:2017

Optical fibre cables - Part 2: Indoor cables - Sectional specification
Newest version Valid from 01.11.2017
Main

EVS-EN IEC 60794-1-22:2018

Optical fibre cables - Part 1-22: Generic specification - Basic optical cable test procedures - Environmental test methods
Withdrawn from 01.04.2021
Main

EVS-EN 50411-2-8:2009

Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-8: Microduct connectors, for air blown optical fibres, Type 1
Newest version Valid from 07.08.2009