This website uses cookies. We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services.

Cookies are small text files that can be used by websites to make a user's experience more efficient.

The law states that we can store cookies on your device if they are strictly necessary for the operation of this site. For all other types of cookies we need your permission.

This site uses several different types of cookies. These cookies can be categorized in three different ways: duration, party or purpose.

 

Duration

Session cookies are used every time you visit the website. They are temporary and expire after closing the browser or ending the session.

 

Persistent cookies have an expiration date, but their duration may vary. These cookies are not deleted after closing the browser and are stored on your device.

 

Parties

First-party cookies are placed directly on your device by our website.

 

Third-party cookies are not placed on your device by the website you are visiting, but by a third party, such as an advertiser or analysis system.

 

Purpose

Necessary cookies are essential for browsing the website and using its features, such as accessing secure areas of the site. Cookies allow the online store to store products in the shopping cart when shopping online. These cookies are generally first-party session cookies.

 

Functionality cookies allow the website to remember choices you have made in the past, such as which language you prefer or what your username is, so that you can log in automatically.

 

Analytical cookies collect information about how you use the website, such as which pages you visited and which links you clicked on. This information cannot be used to identify you and has been anonymized. Their sole purpose is to improve the functionality of the website. This includes cookies from third-party analytics services.

 

Marketing cookies help track online activity to help advertisers deliver more relevant ads or limit the number of times you see an ad. These cookies may share this information with other organizations or advertisers. These are persistent cookies and are almost always of third-party origin.

 

Cookie settings can be changed at any time by clicking on the "Consent" or “Data” link, turning on or off cookie options and clicking on the "Allow selection" link.

 

You can also control the use of functional, analytical and marketing cookies by adjusting your browser settings.

 

More information on the principles for processing of customer data can be found in our privacy info.

Your consent applies to the following domains: www.evs.ee

Your current state: Deny. 

Cookie declaration last updated on 26/03/2025 by Cookiebot:

Necessary (8)

Necessary cookies are essential for user experience by enabling basic functions such as page navigation and access to secure areas. The website cannot function properly without these cookies. These cookies are first-party session cookies. 

Name Provider Purpose Maximum Storage Duration Type
.Nop.Antiforgery www.evs.ee Ensures visitor browsing-security by preventing cross-site request forgery. This cookie is essential for the security of the website and visitor. Session HTTP Cookie
.Nop.Authentication evs.ee Necessary to identify loged in user. Session HTTP Cookie
.Nop.Customer www.evs.ee This cookie allows the user to close the browser and return to the website without losing the items in the shopping-cart.Used to remember which products have been added to shopping-cart. 1 year HTTP Cookie
_GRECAPTCHA Google Cookie is used to provide spam protection. Session HTTP Cookie
CookieConsent Cookiebot Stores the user's cookie consent state for the current domain 1 year HTTP Cookie
language evs.ee Used to store the language preference of the website visitor. 500 years HTTP Cookie
rc::a Google This cookie is used to distinguish between humans and bots. Persistent HTML Local Storage
rc::c Google This cookie is used to distinguish between humans and bots. Session HTML Local Storage

Statistics (1)

Statistics cookies help to understand how visitors interact with the site by collecting and publishing data anonymously. The purpose of these cookies is to help improve website functionality.

Name Provider Purpose Maximum Storage Duration Type
.Nop.RecentlyViewedProducts www.evs.ee Contains data on the latest products viewed by visitors. Session HTTP Cookie
 
Skip to main content
Back
NEW

EVS-EN IEC 61558-2-15:2025

Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations

General information

Valid from 01.04.2025
Base Documents
IEC 61558-2-15:2022; EN IEC 61558-2-15:2025
Directives or regulations
None

Standard history

Status
Date
Type
Name
05.03.2012
Main
This part of IEC 61558 deals with safety of isolating transformers for medical IT systems for the supply of medical locations.
NOTE 1 Safety includes electrical, thermal and mechanical aspects.
Unless otherwise specified, from here onward, the term transformer covers isolating transformers for medical IT systems for the supply of medical locations.
This document is applicable to isolating transformers, single-phase or three-phase, air-cooled (natural or forced) dry-type transformers for the supply of medical IT system for group 2 medical locations, designed to be permanently connected to the fixed wiring and intended to form the medical IT system on the secondary side. The windings can be encapsulated or non encapsulated.
NOTE 2 IT systems are defined in IEC 60364-1.
The installation rules for medical IT system for group 2 medical locations are covered by IEC 60364-7-710.
Transformers covered by this document are intended for medical IT systems for the supply of medical locations. All other transformers or equipments connected downstream from the transformer are not covered by this document.
The rated supply voltage does not exceed 1 000 V AC. The rated supply frequency and internal operational frequency do not exceed 500 Hz.
The rated output does not be less than 0,5 kVA and does not exceed 10 kVA for single-phase and three-phase transformers for medical IT system for group 2 medical locations.
This document may be applicable to isolating transformers intended to supply other medical installations that are not group 2 medical locations without limitation of the rated output subject to an agreement between the purchaser and the manufacturer.
NOTE 3 Transformers intended to supply distribution networks other than medical IT systems are not included in the scope.
The no-load output voltage and the rated output voltage does not exceed 250 V AC for single-phase or three-phase transformer (phase-to-phase voltage).
This document does not cover power supply units and is not intended to be used in conjunction with IEC 61558-2-16 for switch mode power supply units.
This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers.
Transformers covered by this document are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification.
NOTE National installation rules of some countries have different or additional requirements listed in Annex C of IEC 60364-7-710:2021.
Attention is drawn 193 to the following:
- for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.);
- measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing;
- the different conditions for transportation, storage, and operation of the transformers;
- additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments.
This GROUP SAFETY PUBLICATION focusing on SAFETY guidance is primarily intended to be used as a PRODUCT SAFETY STANDARD for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this GROUP SAFETY PUBLICATION, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
One of the RESPONSIBILITIES of a TC is, wherever applicable, to make use of BSPs and/or GSPs in the preparation of its publications.