EVS-EN IEC 61326-3-2:2018

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment

General information

Valid from 19.12.2018
Base Documents
IEC 61326-3-2:2017; EN IEC 61326-3-2:2018
Directives or regulations
None

Standard history

Status
Date
Type
Name
19.12.2018
Main
05.09.2008
Main
This part of IEC 61326 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic
environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, and based on the requirements of the process industry,
specifically chemical/petrochemical/pharmaceutical manufacturing plants using the mitigation measures given in Annex C. The difference between the electromagnetic environment
covered by this document compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment with test values that have been proven in practice.
The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics:
– industrial area with limited access;
– limited use of mobile transmitters;
– dedicated cables for power supply and control, signal or communication lines;
– separation between power supply and control, signal or communication cables;
– factory building mostly consisting of metal construction;
– overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices);
- pipe heating systems driven by AC main power;
- no high-voltage substation close to sensitive areas;
- presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power;
- competent staff;
- periodical maintenance of equipment and systems;
- mounting and installation guidelines for equipment and systems.
Equipment and systems considered as "proven-in-use" according to IEC 61508 or "prior use" according to IEC 61511 are excluded from the scope of this document.
Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of this document.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 61326-3-1:2017

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - General industrial applications
Newest version Valid from 02.08.2017
Main

EVS-EN IEC 61326-1:2021

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
Newest version Valid from 20.07.2021
Main

EVS-EN IEC 61326-2-2:2021

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
Newest version Valid from 15.06.2021
Main + amendment

EVS-EN 15194:2017+A1:2023

Cycles - Electrically power assisted cycles - EPAC Bicycles
Newest version Valid from 01.09.2023