Skip to main content
Back

EVS-EN IEC 61123:2020

Reliability testing - Compliance test plans for success ratio

General information

Valid from 02.03.2020
Base Documents
IEC 61123:2019; EN IEC 61123:2020
Directives or regulations
None

Standard history

Status
Date
Type
Name
02.03.2020
Main
05.07.2006
Main
IEC 61123:2019 is intended to define a procedure to verify if a reliability of an item/system complies with the stated requirements. The requirement is assumed to be specified as the percentage of success (success ratio) or the percentage of failures (failure ratio). This document can be used where a number of items are tested (number of trials performed) and classified as passed or failed. It can also be used where one or a number of items are tested repeatedly. The procedures are based on the assumption that the probability of success or failure is the same from trial to trial (statistically independent events). Plans for fixed trial/failure terminated tests as well as truncated sequential probability ratio tests (SPRTs) are included. This document contains extensive tables with ready-to-use SPRT plans and their characteristics for equal and non-equal risks for supplier and customer. In the case of the reliability compliance tests for constant failure rate/intensity, IEC 61124 applies. This second edition cancels and replaces the first edition published in 1991. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
The sequential probability ratio test (SPRT) [1, 2][1] has been significantly developed in recent years [3, 4, 5]. This edition contains shorter and accurate tests, a wide range of test plans, and significant additional characteristic data, as follows:
the tests are significantly truncated (the maximum trial numbers are low) without substantially increasing the expected number of trials to decision (ENT);
the true producer’s and consumer’s risks (α', β') are given and very close to the nominal (α, β);
the range of the test parameters is wide (failure ratio, risks and discrimination ratio);
the test plans include various risk ratios (not restricted to equal risks only);
the values of ENT are accurate and given in the relevant region (for practical use);
guidelines for extension of the test sets (interpolation and extrapolation) are included.
In Annex C, the use of the cumulative binomial distribution function of Excel that simplifies the procedure of designing has been added (Clause C.3).

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-IEC 60605-2:2006

Equipment reliability testing - Part 2: Design of test cycles
Newest version Valid from 05.07.2006
Main

EVS-IEC 60605-4:2006

Equipment reliability testing - Part 4: Statistical procedures for exponential distribution - Point estimates, confidence intervals, prediction intervals and tolerance intervals
Newest version Valid from 05.07.2006
Main

EVS-IEC 60605-6:2011

Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity
Newest version Valid from 05.01.2011
Main

EVS-EN 61124:2012

Reliability testing - Compliance tests for constant failure rate and constant failure intensity
Withdrawn from 17.04.2023