Skip to main content
Back

EVS-EN 62053-24:2015

Electricity metering equipment (a.c.) - Particular requirements - Part 24: Static meters for reactive energy at fundamental frequency (classes 0,5 S, 1 S and 1)

General information

Withdrawn from 03.05.2021
Base Documents
IEC 62053-24:2014; EN 62053-24:2015
Directives or regulations
None

Standard history

Status
Date
Type
Name
03.05.2021
Main
18.04.2017
Amendment
04.02.2015
Main
This part of IEC 62053 applies only to newly manufactured transformer operated static varhour meters of accuracy classes 0,5 S, and 1 S as well as direct connected static var-hour
meters of accuracy class 1, for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
This standard uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages
only. See Clause 3.
NOTE 1 This differs from the approach of IEC 62053-23, where reactive power and energy is defined only for sinusoidal signals. In this standard reactive power and energy is defined for all periodic signals. Reactive power and energy is defined in this way to achieve proper reproducibility of measurements with meters of different designs. With this definition, reactive power and energy reflects the generally unnecessary current possible to compensate with capacitors rather than the total unnecessary current.
It applies only to static var-hour meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc., are enclosed in the meter case, then the relevant standards for these elements also apply.
NOTE 2 IEC 61869-2:2012 describes transformers having a measuring range of 0,05 In to Imax for accuracy classes 0,2, 0,5, 1 and 2, and transformers having a measuring range of 0,01 In to Imax for accuracy classes 0,2 S and 0,5 S. As the measuring range of a meter and its associated transformers have to be matched and as only transformers of classes 0,2 S / 0,5 S have the current error and phase displacement characteristics suitable to operate a class 0,5 S / 1 S meter respectively as specified in this standard, the measuring range of the transformer operated meters will be 0,01 In to Imax. Reactive meters intended to be used together with non-S transformers are, therefore, not covered by this standard.
It does not apply to:
• var-hour meters where the voltage across the connection terminals exceeds 600 V (lineto-line voltage for meters for polyphase systems);
• portable meters;
• data interfaces to the register of the meter;
• reference meters.
The dependability aspect is covered by the standards of the IEC 62059 series.

Required fields are indicated with *

*
*
*
PDF
24.40 € incl tax
Paper
24.40 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN 62053-24:2015/A1:2017

Electricity metering equipment (a.c.) - Particular requirements - Part 24: Static meters for reactive energy at fundamental frequency (classes 0,5 S, 1 S and 1)
Withdrawn from 03.05.2021
Main

EVS-IEC 60050-466:2016

International Electrotechnical Vocabulary. Chapter 466: Overhead lines
Newest version Valid from 03.01.2017
Main

EVS-EN 62271-1:2017

High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
Valid from 18.12.2017
Main

EVS-EN 61400-25-1:2017

Wind energy generation systems - Part 25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models
Newest version Valid from 18.12.2017