Skip to main content
Back

EVS-EN 61557-15:2014

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems

General information

Valid from 05.06.2014
Base Documents
IEC 61557-15:2014; EN 61557-15:2014
Directives or regulations
2014/35/EU Low voltage (LVD)

Standard history

Status
Date
Type
Name
05.06.2014
Main
IEC 61557-15:2014 specifies requirements related to functional safety and is based on the IEC 61508 standard series for the realization of Insulation Monitoring Devices (IMD) as specified in IEC 61557-8 and for Insulation Fault Location Systems (IFLS) according to IEC 61557-9, according to phase 10 of the IEC 61508-1 lifecycle. These devices provide safety related functions for IT systems. This part of IEC 61557 is  - concerned only with functional safety requirements intended to reduce the functional risk during the use of IMDs and IFLSs;  - restricted to risks arising directly from the device itself or from several IMDs or IFLSs working together in a system; and  - intended to define the basic safety functions provided by the devices. This part of IEC 61557 does not  - deal with electrical safety according to IEC 61010-1 and the requirements of IEC 61557-8 and IEC 61557-9;  - cover the hazard and risk analysis of a particular use of the IMD or IFLS;  - identify all the safety functions for the application in which the IMD or IFLS is used; and  - cover the IMD or IFLS manufacturing process. This part of IEC 61557 is to be used in conjunction with Part 8 and Part 9. Functional safety requirements depend on the application and should be considered as part of the overall risk assessment of the specific application. The supplier of IMDs and IFLSs is not responsible for the application. The application designer is responsible for the risk assessment and for specifying the overall functional safety requirements of the complete IT system and he should select the functional safety level (SIL) of the IMD and/or IFLS when their safety function is part of the functional safety assessment in the IT system.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + corrigendum

EVS-EN ISO 12100:2010

Safety of machinery - General principles for design - Risk assessment and risk reduction
Newest version Valid from 06.12.2010
Main

EVS-EN ISO 14982:2009

Agricultural and forestry machines - Electromagnetic compatibility - Test methods and acceptance criteria
Newest version Valid from 07.08.2009
Main

EVS-EN 61557-8:2015

Electrical safety in low voltage distribution systems up to 1 000 v a.c. And 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: insulation monitoring devices for IT systems
Newest version Valid from 06.10.2015
Main

EVS-EN 60945:2003

Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
Newest version Valid from 01.03.2003