Skip to main content
Back

EVS-EN 61260-1:2014

Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications

General information

Valid from 04.08.2014
Base Documents
IEC 61260-1:2014; EN 61260-1:2014
Directives or regulations
None

Standard history

Status
Date
Type
Name
04.08.2014
Main
05.06.2005
Main
05.06.2005
Amendment
IEC 61260-1:2014 specifies performance requirements for analogue, sampled-data, and digital implementations of band-pass filters. The extent of the pass-band region of a filter's relative attenuation characteristic is a constant percentage of the exact mid-band frequency for all filters of a given bandwidth. An instrument conforming to the requirements of this standard may contain any number of contiguous band-pass filters covering any desired frequency range. Performance requirements are provided for two filter classes: class 1 and class 2. In general, specifications for class 1 and class 2 filters have the same design goals and differ mainly in the acceptance limits and the range of operational temperature. Acceptance limits for class 2 are greater than, or equal to, those for class 1. Maximum-permitted expanded uncertainties of measurement are also specified. Band-pass filters conforming to the performance requirements of this standard may be part of various measurement systems or may be an integral component of a specific instrument such as a spectrum analyser. This standard specifies the ranges of environmental conditions for operation of the filters. The required range depends on whether the instrument containing the filters is designed to be operated in a controlled environment or more generally in the field. Band-pass filters conforming to the requirements of this standard are capable of providing frequency-band-filtered spectral information for a wide variety of signals, for example, time-varying, intermittent or steady; broadband or discrete frequency; and long or short durations. This first edition of IEC 61260-1, future IEC 61260-2 and future IEC 61260-3, cancel and replace the first edition of IEC 61260 (1995) and its amendment 1 (2001). This edition constitutes a technical revision which includes the following significant technical changes with respect to the IEC 61260 (1995) and its amendment 1 (2001):  - the single document in the first edition of IEC 61260 (1995) and its amendment 1 (2001) is in IEC 61260 series separated into the three parts covering: specifications, pattern evaluation tests and periodic tests;  - the performance category class 0 is removed;  - the design goals for the specification can be based only base-10;  - the reference environmental conditions have been changed from 20 °C / 65 % RH to 23 °C / 50 % RH; and  - IEC 61260 (1995) specified tolerance limits without considering the uncertainty of measurement for verification of the specifications. IEC 61260 series specifies acceptance limits for the observed values and maximum-permitted uncertainty of measurements for laboratories testing conformance to specifications in the standard.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 61260-2:2016

Electroacoustics - Octave-band and fractional-octave-band filters - Part 2: Pattern-evaluation tests
Newest version Valid from 05.07.2016
Main

EVS-EN 61260-3:2016

Electroacoustics - Octave-band and fractional-octave-band filters - Part 3: Periodic tests
Newest version Valid from 05.07.2016
Main + amendment

EVS-EN 15461:2008+A1:2010

Railway applications - Noise emission - Characterisation of the dynamic properties of track sections for pass by noise measurements CONSOLIDATED TEKST
Newest version Valid from 05.01.2011
Amendment

IEC 61260-2:2016/AMD1:2017

Amendment 1 - Electroacoustics - Octave-band and fractional-octave band filters - Part 2: Pattern evaluation tests
Newest version Valid from 07.04.2017