Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement (IEC 61010-031:2015 + IEC 61010-031:2015/A1:2018)

General information

Withdrawn from 01.06.2023
Base Documents
IEC 61010-031:2015; EN 61010-031:2015; IEC 61010-031:2015/A1:2018; EN 61010-031:2015/A1:2021; EN 61010-031:2015/A11:2021
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.06.2023
Main
15.12.2021
Main + amendment
01.12.2021
Amendment
EVS-EN 61010-031:2015/A1:2021
01.12.2021
Amendment
EVS-EN 61010-031:2015/A11:2021
05.08.2015
Main
This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment.
a) Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1.)
b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1,5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2).
c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3).
d) Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that are RATED for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c., and are suitable for currents exceeding 8 A (see Figure 4).

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-HD 60364-4-42:2011+A1+A11:2021

Low voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects (IEC 60364-4-42:2010, modified + IEC 60364-4-42:2010/A1:2014)
Newest version Valid from 31.12.2021
Main + amendment

EVS-EN 62271-1:2017+A1:2022

High-voltage switchgear and controlgear. Part 1: Common specifications for alternating current switchgear and controlgear (IEC 62271-1:2017 + IEC 62271-1:2017/AMD1:2021)
Newest version Valid from 01.02.2022
Main

EVS-EN ISO 3834-2:2021

Quality requirements for fusion welding of metallic materials - Part 2: Comprehensive quality requirements (ISO 3834-2:2021)
Newest version Valid from 17.05.2021
Main

EVS-EN IEC 61557-1:2021

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements (IEC 61557-1:2019)
Newest version Valid from 15.12.2021