EVS-EN 61000-3-3:2013

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

General information

Valid from 07.10.2013
Base Documents
IEC 61000-3-3:2013; EN 61000-3-3:2013

Standard history

Status
Date
Type
Name
Amendment
EN 61000-3-3:2013/prAA
01.09.2022
Main + amendment
01.12.2021
Amendment
15.08.2019
Amendment
15.08.2019
Main + amendment
07.10.2013
Main
This part of IEC 61000 is concerned with the limitation of voltage fluctuations and flicker
impressed on the public low-voltage system.
It specifies limits of voltage changes which may be produced by an equipment tested under
specified conditions and gives guidance on methods of assessment.
This part of IEC 61000 is applicable to electrical and electronic equipment having an input
current equal to or less than 16 A per phase, intended to be connected to public low-voltage
distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to
conditional connection.
Equipment which does not comply with the limits of this part of IEC 61000 when tested with
the reference impedance Zref of 6.4, and which therefore cannot be declared compliant with
this part, may be retested or evaluated to show conformity with IEC 61000-3-11. Part 3-11 is
applicable to equipment with rated input current ≤ 75 A per phase and subject to conditional
connection.
The tests according to this part are type tests. Particular test conditions are given in Annex A
and the test circuit is shown in Figure 1.
NOTE 1 The limits in this standard relate to the voltage changes experienced by consumers connected at the
interface between the public supply low-voltage network and the equipment user’s installation. Consequently, if the
actual impedance of the supply at the supply terminals of equipment connected within the equipment user’s
installation exceeds the test impedance, it is possible that supply disturbance exceeding the limits could occur.
NOTE 2 The limits in this standard are based mainly on the subjective severity of flicker imposed on the light from
230 V 60 W coiled-coil filament lamps by fluctuations of the supply voltage. For systems with nominal voltage less
than 220 V line to neutral and/or frequency of 60 Hz, the limits and reference circuit values are under
consideration.

Required fields are indicated with *

*
*
*
PDF
24.40 € incl tax
Paper
24.40 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 61000-3-2:2014

Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
Withdrawn from 15.04.2019
Main

EVS-EN 61000-4-4:2012

Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4:2012)
Newest version Valid from 05.12.2012
Main

EVS-EN 61000-4-2:2009

Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
Newest version Valid from 04.06.2009
Main

EVS-EN 61000-4-6:2014

Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Withdrawn from 15.08.2023