EVS-EN 60079-7:2015

Explosive atmospheres - Part 7: Equipment protection by increased safety "e"

General information

Valid from 05.01.2016
Base Documents
IEC 60079-7:2015; EN 60079-7:2015

Standard history

Status
Date
Type
Name
Main
prEN IEC 60079-7:2024
01.02.2024
Amendment
01.02.2024
Main + amendment
03.02.2020
Main + amendment
01.02.2018
Amendment
05.01.2016
Main
06.03.2007
Main
IEC 60079-7:2015(E) specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres. Electrical equipment and Ex Components of type of protection increased safety "e" are either:

- Level of Protection "eb" (EPL "Mb" or "Gb");

- or Level of Protection "ec" (EPL "Gc"). Level of Protection "eb" applies to equipment or Ex Components, including their connections, conductors, windings, lamps, and batteries; but not including semiconductors or electrolytic capacitors. Level of Protection "ec" applies to equipment or Ex Components, including their connections, conductors, windings, lamps, and batteries; and also including semiconductors and electrolytic capacitors. The requirements of this standard apply to both Levels of Protection unless otherwise stated. For Level of Protection "eb", this standard applies to electrical equipment where the rated voltage does not exceed 11 kV r.m.s., a.c. or d.c. For Level of Protection "ec", this standard applies to electrical equipment where the rated voltage does not exceed 15 kV r.m.s., a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fifth edition cancels and replaces the fourth edition published in 2006, and constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 5.0 and previous edition of the document.
Keywords: electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres.

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN IEC 60079-7:2015/A1:2018

Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Valid from 01.02.2018
Main

EVS-EN 60079-1:2014

Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Valid from 07.11.2014
Main

EVS-EN 60079-11:2012

Explosive atmospheres -- Part 11: Equipment protection by intrinsic safety "i"
Withdrawn from 16.12.2024
Main + corrigendum

EVS-EN IEC 60079-0:2018

Explosive atmospheres - Part 0: Equipment - General requirements
Valid from 16.07.2018