Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"

General information

Valid from 05.01.2016
Base Documents
IEC 60079-6:2015; EN 60079-6:2015

Standard history

Status
Date
Type
Name
16.12.2024
Amendment
05.01.2016
Main
06.08.2007
Main
IEC 60079-6:2015 specifies the requirements for the design, construction, testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion "o" intended for use in explosive gas atmospheres. Ex Equipment and Ex Components of type of protection liquid immersion "o" are either:

- Level of Protection "ob" (EPL "Mb" or "Gb") or

- Level of Protection "oc" (EPL "Gc"). For Level of Protection "ob", this standard applies where the rated voltage does not exceed 11 kV r.m.s. a.c. or d.c. For Level of Protection "oc", this standard applies where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition, published in 2007. This edition constitutes a technical revision. The significant changes with respect to the previous edition are:

- Edition 4 represents a major technical revision of the requirements for oil immersion "o" and should be considered as introducing all new requirements. The normal "Table of Significant Changes" has not been included for this reason. In particular:

- The requirements for oil immersion "o" have been redefined into liquid immersion, levels of protection "ob" and "oc" as recommended by the responses to 31/715/DC;

- The ability to protect sparking contacts has been added to both "ob" and "oc". Additional requirements have been introduced for the protective liquid.
Keywords: Ex Equipment and Ex Components with type of protection liquid immersion "o"

Required fields are indicated with *

*
*
*
PDF
19.52 € incl tax
Paper
19.52 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 60079-18:2015

Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
Newest version Valid from 07.05.2015
Main

EVS-EN 60079-2:2015

Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
Newest version Valid from 04.02.2015
Main + corrigendum

EVS-EN IEC 60079-0:2018

Explosive atmospheres - Part 0: Equipment - General requirements
Valid from 16.07.2018
Main

EVS-EN 60079-5:2015

Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
Newest version Valid from 07.05.2015