EVS-EN 60079-28:2015+A11:2024

Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation (IEC 60079-28:2015)

General information

Valid from 01.02.2024
Base Documents
IEC 60079-28:2015; EN 60079-28:2015; IEC 60079-28:2015/ISH1:2019; EN 60079-28:2015/A11:2024
Directives or regulations
None

Standard history

Status
Date
Type
Name
Main
prEN IEC 60079-28:2024
01.02.2024
Main + amendment
01.02.2024
Amendment
06.10.2015
Main
This part of IEC 60079 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb.
This standard contains requirements for optical radiation in the wavelength range from 380 nm to 10 m. It covers the following ignition mechanisms:
•  Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this may allow them to attain a temperature which will ignite a surrounding explosive atmosphere.
•  In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point.
NOTE 1 See a) and d) of the introduction.
This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard.
This standard specifies requirements for equipment intended for use under atmospheric conditions.
This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence.
This standard applies to optical fibre equipment and optical equipment, including LED and laser equipment, with the exception of the equipment detailed below:
1)  Non-array divergent LEDs used for example to show equipment status or backlight function.
2)  All luminaires (fixed, portable or transportable), hand lights and caplights; intended to be supplied by mains (with or without galvanic isolation) or powered by batteries:
–  with continuous divergent light sources (for all EPLs),
–  with LED light sources  (for EPL Gc or Dc only).
NOTE 2 Continuous divergent LED light sources for other than EPL Gc or Dc are not excluded from the standard due to the uncertainty of potential ignition concerns regarding high irradiance.
3)  Optical radiation sources for EPL Mb, Gb or Gc and Db or Dc applications which comply with Class 1 limits in accordance with IEC 60825-1.
NOTE 3 The referenced Class 1 limits are those that involve emission limits below 15 mW measured at a distance from the optical radiation source in accordance with IEC 60825-1, with this measured distance reflected in the Ex application.
4)  Single or multiple optical fibre cables not part of optical fibre equipment if the cables:
–  comply with the relevant industrial standards, along with additional protective means, e.g. robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc),
–  comply with the relevant industrial standards (for EPL Gc or Dc).
5)  Enclosed equipment involving an enclosure that fully contains the optical radiation and that complies with a suitable type of protection as required by the involved EPL, with the enclosure complying with one of the following conditions:
–  An enclosure for which an ignition due to optical radiation in combination with absorbers inside the enclosure would be acceptable such as flameproof "d" enclosures (IEC 60079-1), or
–  An enclosure for which protection regarding ingress of an explosive gas atmosphere is provided, such as pressurized "p" enclosures (IEC 60079-2), restricted breathing “nR” enclosure (IEC 60079-15), or
–  An enclosure for which protection regarding ingress of an explosive dust atmosphere is provided, such as  dust protection "t" enclosures" (IEC 60079-31), or
–  An enclosure for which protection regarding ingress of absorbers is provided (such as IP 6X enclosures) and where no internal absorbers are to be expected.
NOTE 4 For these scope exclusions based on enclosure constructions, it is anticipated that the enclosures are not opened in the explosive atmosphere, so that ingress is protected.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 60079-1:2014+A11:2024

Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" (IEC 60079-1:2014)
Newest version Valid from 01.02.2024
Main + amendment

EVS-EN IEC 60079-0:2018+A11:2024

Explosive atmospheres - Part 0: Equipment - General requirements (IEC 60079-0:2017 + COR1:2020)
Newest version Valid from 01.02.2024
Main + corrigendum

EVS-EN 60079-14:2014

Explosive atmospheres -- Part 14: Electrical installations design, selection and erection
Newest version Valid from 06.10.2014
Main

EVS-EN 62471:2008

Photobiological safety of lamps and lamp systems
Newest version Valid from 07.11.2008