EVS-EN 60044-1:2002+A2:2003

Instrument transformers - Part 1: Current transformers

General information

Withdrawn from 04.07.2013
Base Documents
IEC 60044-1:1996 + IEC 60044-1/A1:2000 + IEC 60044-1/A2:2002; EN 60044-1:1999 + EN 60044-1:1999/A1:2000 + EN 60044-1:1999/A2:2003
Directives or regulations
None

Standard history

Status
Date
Type
Name
04.07.2013
Main
Main + amendment
Main
EVS-EN 60044-1:2002
Amendment
EVS-EN 60044-1:2002/A2:2003
This part of IEC 44 applies to newly manufactured current transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz.
Although the requirements relate basically to transformers with separate windings, they are also applicable, where appropriate, to autotransformers.
Clause 11 covers the requirements and tests, in addition to those in clauses 3 to 10, that are necessary for current transformers for use with electrical measuring instruments.
Clause 12 covers the requirements and tests, in addition to those in clauses 3 to 10, that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the maintenance of accuracy up to several times the rated current.
For certain protective systems, where the current transformer characteristics are dependant on the overall design of the protective equipment (for example high-speed balanced systems and earth-fault protection in resonant earthed networks), additional requirements are given in clause 13 for class PR transformers and in clause 14 for class PX transformers.
Clause 13 covers the requirements and tests in addition to those in clauses 3 to 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the absence of remanent flux.
Clause 14 covers the requirements and tests in addition to those in clauses 3 to 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection for which knowledge of the transformer’s secondary excitation characteristic, secondary winding resistance, secondary burden resistance and turns ratio is sufficient to assess its performance in relation to the protective relay system with which it is to be used.
Current transformers intended for both measurement and protection shall comply with all the clauses of this standard.
Instrument transformers (ITs) are consdered to be passive elements.
NOTE: For outdoor ITs having voltages ≥ 123 kV the RIV measurements are suitable to cover the requirements of EMC Directive. For guidance of the test procedure EN 60694:1996, § 6.3 might be followed.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 60044-2:2002+A2:2003

Instrument transfomers - Part 2: Inductive voltage transformers
Withdrawn from 05.03.2012
Main

EVS-ISO 11799:2005

Information and documentation - Document storage requirements for archive and library materials
Withdrawn from 03.05.2016
Main

EVS-HD 60364-4-43:2010

Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
Withdrawn from 15.09.2023
Main + corrigendum

EVS-HD 60364-5-551:2010

Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment - Clause 551: Low-voltage generating sets
Newest version Valid from 08.04.2010