Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration

General information

Valid from 04.03.2015
Base Documents
CISPR 16-1-6:2014; EN 55016-1-6:2015
Directives or regulations
None

Standard history

Status
Date
Type
Name
02.05.2022
Amendment
02.05.2022
Main + amendment
02.06.2017
Amendment
04.03.2015
Main
This part of CISPR 16 provides procedures and supporting information for the calibration of antennas for determining antenna factors (AF) that are applicable to antennas intended for use in radiated disturbance measurements.
It has the status of a basic EMC Standard in accordance with IEC Guide 107, Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications.
The AF of an antenna is influenced by nearby surroundings and by its position in space relative to the radiating source. This standard focuses on antenna calibrations that provide the AF in a free-space environment in the direction of the boresight of the antenna. The frequency range addressed is 9 kHz to 18 GHz. The relevant antenna types covered in this standard are monopole, loop, dipole, biconical, log-periodic dipole-array (LPDA), hybrid and horn antennas.
Guidance is also provided on measurement uncertainties associated with each calibration method and configuration, and the test instrumentation used.

Required fields are indicated with *

*
*
*
PDF
46.36 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN 55016-1-6:2015/A1:2017

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration
Valid from 02.06.2017
Main

EVS-EN 55016-1-5:2015

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
Newest version Valid from 04.03.2015
Main

EVS-EN 55016-2-4:2004

Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements
Newest version Valid from 10.12.2004
Main

EVS-EN 55016-4-2:2011

Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
Newest version Valid from 02.11.2011