EVS-EN 50518:2019

Monitoring and alarm receiving centre

General information

Valid from 02.09.2019
Base Documents
EN 50518:2019
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.05.2023
Amendment
15.05.2023
Main + amendment
02.09.2019
Main
09.12.2013
Main
09.12.2013
Main
09.12.2013
Main
This European Standard specifies the minimum requirements for monitoring, receiving and processing of alarm messages generated by alarm systems taking place as a part of the total fire, safety and security solution.
For the purpose of this standard, the term "alarm" is used in the broad sense to include fault, status and other messages received from one or more of a range of safety and security alarm systems such as but not limited to fire detection and fire alarm systems, fixed fire fighting systems, intrusion and hold-up alarm systems, access control systems, video surveillance systems, social alarms systems and combinations of such systems.
This standard gives requirements for two categories of ARC, category I and category II. A category I ARC will be designed, constructed and operated to a higher standard with respect to construction, security and integrity than a category II ARC.
The categorization is determined according to the type(s) of alarm messages handled.
Category I: ARCs handling messages from security applications:
-  I&HAS’s;
-  access control systems;
-  VSS in security applications that require an emergency response (for example loss prevention);
-  people monitoring, lone workers and object tracking systems for security applications;
-  alarm messages handled by category II ARCs;
-  combinations of the above systems.
Category II: ARC’s handling messages from non-security applications:
-  fire alarm systems;
-  fixed firefighting systems;
-  social alarm systems;
-  audio/video door entry systems;
-  VSS in non-security applications (for example traffic flow);
-  people monitoring, lone workers and object tracking systems for non-security applications;
-  elevator emergency systems;
-  combinations of the above systems.
The requirements apply to ARC’s (whether established in single or multiple sites) monitoring and processing alarms generated by systems installed at other locations and also to ARC’s monitoring solely alarms from systems within their own site.
The standard includes functional and specific requirements supporting the services of an ARC.
The standard does NOT apply to
-  alarm systems used for non-civil purposes;
-  alarm systems for medical or health applications.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO/IEC 27001:2017

Information technology - Security techniques - Information security management systems - Requirements (ISO/IEC 27001:2013 including Cor 1:2014 and Cor 2:2015)
Withdrawn from 15.08.2023
Main

CLC/TS 50131-12:2016

Alarm systems - Intrusion and hold-up systems - Part 12: Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS)
Newest version Valid from 06.12.2016
Amendment

EVS-EN 50136-1:2012/A1:2018

Alarm systems - Alarm transmission systems and equipment - Part 1: General requirements for alarm transmission systems
Newest version Valid from 16.11.2018
Main

EVS-ISO 21001:2018

Educational organizations - Management systems for educational organizations - Requirements with guidance for use (ISO 21001:2018, identical)
Valid from 16.05.2018