Residential solid fuel burning appliances - Part 1: General requirements and test methods

General information

Valid from 15.03.2023
Base Documents
EN 16510-1:2022
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.03.2023
Main
01.08.2018
Main
05.09.2008
Corrigendum
08.10.2007
Corrigendum
08.10.2007
Corrigendum
05.01.2005
Amendment
05.01.2005
Amendment
05.01.2005
Amendment
01.06.2003
Amendment
04.02.2002
Main
04.02.2002
Main
04.02.2002
Main
09.01.2002
Main
This document is applicable to residential solid fuel burning appliances of which the nominal space heat output is more than 6 % of the combined nominal space heat output and nominal water heat output (total heat output).
This document specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as “appliance(s)”) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity, i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This document specifies CO, NOx, OGC and particulate matter (PM) emission test methods.
This document is as well applicable to appliances intended to carry the load of a chimney.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.
This document is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This document is not applicable to appliances with a boiler intended for water systems having:
—  water temperatures above 110 °C and/or an operating pressure of more than 300 kPa (3 bar);
—  direct contact with sanitary hot water.
This document is not applicable to appliances to be operated with ventilating systems which are intended to operate with pressure below -15 Pa in the room of installation of the appliance in relation to the outside atmosphere.

Required fields are indicated with *

*
*
*
PDF
46.36 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 16510-2-6:2023

Residential solid fuel burning appliances - Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers
Newest version Valid from 15.03.2023
Main

EVS-EN 16510-2-1:2023

Residential solid fuel burning appliances - Part 2-1: Roomheaters
Newest version Valid from 15.03.2023
Main

EVS-EN 16510-2-4:2023

Residential solid fuel burning appliances - Part 2-4: Independent boilers - Nominal heat output up to 50 kW
Newest version Valid from 15.03.2023
Main

EVS-EN 16510-2-3:2023

Residential solid fuel burning appliances - Part 2-3: Cookers
Newest version Valid from 15.03.2023