Skip to main content
Back

CEN/TR 15728:2008

Design and Use of Inserts for Lifting and Handling of Precast Concrete - Elements

General information

Withdrawn from 02.03.2016
Base Documents
CEN/TR 15728:2008
Directives or regulations
None

Standard history

Status
Date
Type
Name
02.03.2016
Main
07.08.2008
Main
This Technical Report provides recommendations for the choice and use of cast-in steel lifting inserts, hereafter called 'inserts' for the handling of precast concrete elements. They are intended for use only during transient situations for lifting and handling, and not for the service life of the structure. The choice of insert is made according to the lifting capacity of their part embedded in the concrete, or may be limited by the capacity of the insert itself and the corresponding key declared by the insert manufacturer. The report covers commonly used applications (walls/beams/columns and solid slabs and pipes) and the range of these applications is further limited to prevent other types of failure than concrete breakout failure (cone failure), failure of supplementary reinforcement or failure in the steel insert. A basic supposition is that the concrete is demonstrably uncracked during all lifting situations. The limitation in scope is used to obtain simple design models. Further information may be found in [1]. The recommended safety levels are intended for short-term-handling and transient situations.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring